Log in
|
Specification |
Details |
|
Drug Detected |
3,4-Methylenedioxypyrovalerone (MDPV) |
|
Common Name |
Bath Salts |
|
Cutoff Level |
1000 ng/mL |
|
Sample Type |
Human Urine |
|
Test Format |
Rapid Test Strip |
|
Time to Results |
Approximately 5 Minutes |
|
Intended Use |
Professional & Forensic Use Only |
Using the test strip is quick and simple:
Remove the test strip from its sealed pouch and use it immediately.
Hold the strip by the labeled end and avoid touching the test membrane.
Dip the test strip vertically into the urine specimen for 10–15 seconds, ensuring the urine level does not exceed the MAX line.
Remove the strip and place it on a clean, flat, non-absorbent surface.
Allow the test to develop and read the results within 3–5 minutes. Do not interpret results after 10 minutes.
Following the recommended testing procedure helps ensure reliable and accurate preliminary screening results
3,4-Methylenedioxypyrovalerone (MDPV) is a synthetic stimulant that belongs to the synthetic cathinone class of substances. It is commonly associated with products marketed as "bath salts", although these products are not intended for bathing and may contain various synthetic stimulant compounds.
MDPV acts on the central nervous system and can produce stimulant effects similar to other powerful stimulants. Due to its high potential for misuse and associated health risks, MDPV is included in specialized professional drug screening programs
MDPV has no approved routine medical use in most countries and is primarily recognized as a controlled synthetic stimulant because of its abuse potential.
Illicit products marketed as "bath salts" often contain MDPV or related synthetic cathinones. Since product formulations may vary, professional drug screening plays an important role in identifying possible MDPV exposure
MDPV is misused for its stimulant effects, which may include increased energy, alertness, and euphoria. However, misuse can also produce serious physical and psychological effects.
Because of its high abuse potential, MDPV testing is commonly used in:
Treatment and rehabilitation programs
Workplace drug testing
Probation and parole monitoring
Correctional facilities
Forensic investigations
Institutional drug screening
The effects of MDPV may vary depending on dosage and individual response. Reported effects may include:
Increased energy
Euphoria
Increased alertness
Restlessness
Anxiety
Agitation
Rapid heart rate
Elevated blood pressure
Insomnia
Hallucinations
Paranoia
High doses may increase the risk of severe psychological and cardiovascular complications requiring immediate medical attention
MDPV and related synthetic cathinones are commonly known by names such as:
Bath Salts
MDPV
Ivory Wave
Vanilla Sky
White Lightning
Cloud Nine
Bloom
White Dove
Street names and product branding frequently change depending on the manufacturer and region
The MDPV Drug Test Strips provide several advantages for professional drug screening:
Rapid preliminary results in approximately 5 minutes
1000 ng/mL screening cutoff
Simple dip-and-read testing procedure
No laboratory equipment required
Easy interpretation of results
Reliable preliminary screening
CLIA-waived design
Suitable for routine and high-volume testing
Designed for professional and forensic environments
For reliable performance:
Store the test strips according to the recommended storage conditions.
Keep each strip sealed in its original pouch until ready for use.
Use the strip immediately after opening the pouch.
Do not use the product after its expiration date.
Protect the test from excessive heat, humidity, and direct sunlight.
Handle urine specimens using appropriate laboratory safety procedures
The MDPV Drug Test Strips provide preliminary qualitative screening results only.
A positive result indicates the possible presence of MDPV (3,4-Methylenedioxypyrovalerone) above the screening cutoff but does not determine the amount consumed, frequency of use, or level of impairment.
A negative result does not necessarily exclude MDPV use if the concentration is below the cutoff level or outside the detection window.
Individual metabolism, specimen quality, collection procedures, and testing conditions may influence test results.
Any preliminary positive result should be confirmed using GC-MS or LC-MS/MS before legal, employment, medical, or administrative decisions are made
The MDPV Drug Test Strip detects 3,4-Methylenedioxypyrovalerone (MDPV), a synthetic cathinone commonly associated with products marketed as bath salts.
This test uses a 1000 ng/mL cutoff level for detecting MDPV in human urine.
Results are available in approximately 5 minutes when the testing instructions are followed correctly.
Yes. The MDPV Drug Test Strips are suitable for professional drug screening in workplaces, treatment centers, probation programs, schools, healthcare facilities, correctional institutions, and forensic laboratories.
No. This product is intended for professional and forensic use only and is not intended for medical or diagnostic purposes.
No. This test provides preliminary screening results only. Any preliminary positive result should be confirmed using Gas Chromatography–Mass Spectrometry (GC-MS) or Liquid Chromatography–Tandem Mass Spectrometry (LC-MS/MS)
The MDPV Drug Test Strips provide a fast, accurate, and dependable solution for the preliminary detection of 3,4-Methylenedioxypyrovalerone (MDPV), commonly known as Bath Salts, in human urine. Featuring a 1000 ng/mL cutoff level, rapid 5-minute results, and an easy dip-and-read format, these professional test strips are well suited for routine and high-volume drug screening.
Designed for use in treatment and rehabilitation centers, workplaces, schools, correctional facilities, healthcare organizations, and forensic laboratories, the test delivers reliable preliminary results without the need for specialized laboratory equipment or technical training. Its CLIA-waived design, straightforward operation, and consistent performance make it an effective choice for professional drug testing programs.
As with all rapid immunoassay screening devices, any preliminary positive result should be confirmed using Gas Chromatography–Mass Spectrometry (GC-MS) or Liquid Chromatography–Tandem Mass Spectrometry (LC-MS/MS) before legal, employment, medical, or administrative decisions are made.
The MDPV Drug Test Strips are rapid urine screening devices designed for the qualitative detection of 3,4-Methylenedioxypyrovalerone (MDPV), commonly referred to as bath salts, in human urine. Using a simple dip-and-read format, these professional test strips provide preliminary results in approximately 5 minutes, making them an efficient solution for routine and high-volume drug screening.
Designed with a 1,000 ng/mL cutoff level, the MDPV Drug Test Strips deliver dependable preliminary screening with high accuracy. Their simple testing procedure requires no laboratory equipment or specialized training, making them suitable for fast on-site screening in a variety of professional settings.
These CLIA-waived test strips are designed for use in clinics, treatment centers, workplaces, schools, correctional facilities, and forensic laboratories. The compact dip-strip format offers convenient specimen testing while supporting efficient screening programs.
The MDPV Drug Test Strips provide preliminary qualitative screening results only. Any preliminary positive result should be confirmed using an appropriate laboratory confirmation method such as Gas Chromatography–Mass Spectrometry (GC-MS) or Liquid Chromatography–Tandem Mass Spectrometry (LC-MS/MS).
This product is intended for professional and forensic use only and is not intended for medical diagnosis
The MDPV Drug Test Strips are intended for professional and forensic use only and are not intended for medical diagnosis or home use.
MDPV is generally detectable in urine for approximately 1–3 days after use. Detection time may vary depending on dosage, frequency of use, metabolism, hydration, and individual health factors.
Frequent or heavy use may extend the detection window
This MDPV Drug Test Strip uses a screening cutoff of:
3,4-Methylenedioxypyrovalerone (MDPV): 1000 ng/mL
Samples at or above this concentration may produce a preliminary positive result and should be confirmed using an appropriate laboratory confirmation method
A colored line appears in both the Control (C) and Test (T) regions. Even if the Test (T) line appears faint, the result should be interpreted as negative, indicating that the concentration of 3,4-Methylenedioxypyrovalerone (MDPV) is below the 1000 ng/mL cutoff level
A colored line appears only in the Control (C) region, while no visible line appears in the Test (T) region. This indicates that MDPV (Bath Salts) may be present at or above the 1000 ng/mL screening cutoff.
Because this device provides preliminary screening results only, all positive results should be confirmed using a more specific laboratory method such as Gas Chromatography–Mass Spectrometry (GC-MS) or Liquid Chromatography–Tandem Mass Spectrometry (LC-MS/MS)
If the Control (C) line does not appear, the test result is invalid, regardless of whether a Test line is visible. This may occur due to insufficient specimen volume, improper testing procedure, or a defective test strip.
Repeat the test using a new strip and a fresh urine specimen

MDPV Drug Test Strips (Bath Salts) 1,000 ng/mL | Serenity SM-DOA-MDPVSP 25/Box